HVAC FAQ

Common questions about the measurements and terms behind your heating and cooling system, answered in plain English by the veteran-owned team at Valor Air. For a deeper walkthrough, see our guide, Understanding Key HVAC Definitions for Optimal System Performance.

What is superheat in an AC system?

Superheat is how many degrees the refrigerant vapor has risen above its boiling (saturation) temperature, usually measured at the evaporator outlet. It confirms all the liquid refrigerant has boiled off before reaching the compressor — protecting that expensive part — and that the system is absorbing heat properly.

What is subcooling?

Subcooling is the opposite of superheat: how many degrees the liquid refrigerant has dropped below its saturation temperature on the high-pressure side. Proper subcooling keeps refrigerant fully liquid until it reaches the metering device and is one of the clearest signs of a correctly charged, efficient system.

What is a good Delta-T (temperature differential) for my AC?

Delta-T is the difference between the cool air from your supply vents and the warmer air returning through the return grille. As a general guideline, supply air should be roughly 15–20°F cooler than the return air. A reading that is too small or too large can both point to a problem such as low refrigerant, restricted airflow, or a dirty coil.

What is SEER2 and why did it replace SEER?

SEER2 (Seasonal Energy Efficiency Ratio 2) measures how efficiently a system cools across the season. As of January 2023, the U.S. Department of Energy updated the test procedure from the original SEER to SEER2, using conditions closer to a real-world installation. A higher SEER2 number means more cooling per unit of energy. AHRI independently certifies these ratings.

What is the difference between SEER and IEER?

SEER2 is a residential rating built around how a home system performs over a cooling season. IEER (Integrated Energy Efficiency Ratio), defined by AHRI under standard 340/360, is the commercial equivalent for larger rooftop and packaged equipment. Because commercial units spend most of their time at part load, IEER is a weighted average of efficiency at 100%, 75%, 50%, and 25% load — weighted toward the lower loads where most operating cost occurs. The two numbers are measured differently and should not be compared directly.

What does refrigerant charge mean?

Charge is the amount of refrigerant in the system. Manufacturers specify an exact amount — too little or too much both reduce efficiency, waste energy, and can shorten the compressor life. Refrigerant handling is regulated under EPA Section 608 and is work for a licensed professional, not a DIY top-off.

What is a TXV (thermostatic expansion valve)?

The TXV is the metering device that controls how much refrigerant flows into the evaporator coil. By modulating that flow it maintains proper superheat and keeps liquid refrigerant away from the compressor. A healthy TXV improves both efficiency and equipment lifespan.

Why does my technician check refrigerant pressures?

The high-side (condensing) and low-side (evaporating) pressures tell a trained technician how well the refrigerant cycle is running — how effectively heat is being rejected outdoors and absorbed indoors. Pressures outside the expected range are an early sign of issues like low charge, airflow restriction, or a struggling compressor.

Have a question we did not cover?